Digital differential thermostat

Solar water heating control for up to 4 boilers per device, expandable to a network of up to 40 boilers.

4boilers per device
40boilers with 10 devices
0.5°Ctemperature accuracy
KIOUR DT5 digital differential thermostat
DT5 · Product image
DEVICE & APPLICATION

From solar collector to water tanks

DT5 monitors the solar collector temperature and individual boiler temperatures, controlling circulation and the corresponding valves. The campaign poster illustrates a four-boiler application, terminal connections and multi-device networking.

DT5 campaign poster with illustrative engineering schematics
KEY FEATURES

Built for flexible installations

Up to 4 boilers

Control four boilers from a single unit.

Master / Slave networking

Connect up to 10 devices to serve 40 boilers with one solar collector.

NTC / PTC sensors

Monitor solar collector and individual boiler temperatures.

Five relay outputs

One output for the circulation pump and four for boiler valves.

Two control modes

Sequential heating or priority-based heating.

DIN rail mounting

Compact housing, 70 × 90 × 65 mm.

OPERATING MODES

A control strategy for every system

SEL = 0

Sequential heating

Boilers requesting heat are served in sequence for a configurable time (tCo). This mode is also used in multi-device networks.

SEL = 1

Priority-based heating

The first boiler is given priority, followed by the others according to their heating demand.

Priority mode (SEL=1) is available only when operating a standalone device, not in a Master/Slave network.
TECHNICAL OVERVIEW

DT5 at a glance

ApplicationSolar water heating systems
CapacityUp to 4 boilers per DT5 / up to 40 boilers networked
SensorsNTC / PTC, up to 5 temperature sensors
Temperature resolution0.5°C
Outputs5 relays: pump + 4 boiler valves
Operating modesSequential / priority-based heating